WENTION TECHNOLOGY SDN BHD

Your Most Reliable Factory Automation Channel

PRODUCTS

FP-X

High Performance, Multiple Functions, and Strengthened Lineup to Support a Wider Variety of Applications.

UL/C-UL , CE Approved

Share this

High Performance

High-speed Operation

The 32-bit RISC processor provides the top-level processing speed in compact PLCs. The scan time is 2 ms or less for 5,000 steps*1. A high-speed PLC is indispensable for enhancing the functionality of equipment.

 

Large Capacity Program Memory

FP-X, which is equipped with 32k steps*2 program memory, is ideal for fully covering the increasing functions, such as communications, positioning, and analog control. The sufficient program capacity can also support future equipment modifications.

 

Independent Comment Memory

There are difficulties with program management on a PC, such as identifying the latest program. The use of the program in the PLC of equipment in operation is often regarded as the best option. Since FP-X has an independent comment memory, all comments can be stored in the PLC together with programs, facilitating program management and maintenance.

 

Maximum Number of I/O Points

Since up to eight expansion units can be connected to one control unit, the maximum number of I/O points is 300. Furthermore, with the add-on cassette and expansion FP0 adapter connected, the number of I/O points can be increased to 382.
*1 Basic instructions: 40%, Data transfer and operation instructions: 60%
*2 C14: 16k steps

Lineup

Control Unit: 18 Types

(14, 30 or 60 points) * (Relay, NPN or PNP) * (AC or DC)

Expansion Unit: 11 Types

(16 points) * (Relay, NPN or PNP)
(30 points) * (Relay, NPN or PNP) * (AC or DC)
(16 points only input)
(14 points only relay output)

Ry output NPN output PNP output
AC DC AC DC AC DC
Control unit 14 points Available Available Available Available Available Available
30 points Available Available Available Available Available Available
60 points Available Available Available Available Available Available
Expansion unit 14 points

Available
(without a power supply section)

16 points

Available
(without a power supply section)

Available
(without a power supply section)

Available
(without a power supply section)

30 points Available Available Available Available Available Available

97 Combinations (Number of I/O Points)

14 to 300 points

Add-on Cassette: 16 Types *3

Digital I/O, Pulse I/O, Analog I/O, Communication (RS485, RS232C, Ethernet), External memory
*3 Please read the ‘Limitation of use’ before using FP-X Add-on cassettes.

 

Network

Up to Three Channels

Three channels are available with a combination of a communication cassette (two-channel type) and the tool port. The combinations of a wide variety of communication functions can support diversified applications.

Ethernet

With a communication cassette (Ethernet type), inspection data, production data, and error information can be easily collected.

Modbus-RTU

Communications with equipment compatible with Modbus-RTU (binary), a worldwide de-facto standard, are available without programming. E.g. temperature controllers and inverters

PLC Link

With a communication cassette (RS485 type), bit data/word data can be easily shared among up to 16 FP-X units.

Computer Link

Easy communications with equipment compatible with Panasonic’s open protocol “MEWTOCOL” are available without programming. E.g. displays, image processors, temperature controllers, and power meters

General-purpose Serial Communications

Commands are generated/transmitted in accordance with the communication protocol of the target equipment.
Or, nonprocedural data receiving is available. E.g. measuring instruments, barcode readers, and RF-ID

 

Positioning

Built-in 4-axis Pulse Output (Transistor Output Type)

The transistor output type C14 comes with 3-axis while C30/60 comes with 4-axis pulse output built-in the control unit. The multi-axis control, which previously required a higher-level PLC or additional positioning unit, or two or more PLC units, can now be achieved with only one FP-X transistor output type unit in a small space at a low cost. In addition, as this type does not require a pulse I/O cassette needed for a relay output type, other function expansion cassettes such as communication or analog input can be attached for more diversified applications.

Specifications

Item Description
Relay output type Transistor output type
Power supply and I/O Specifications Power supply 100 to 240 V AC (AC power), 24 V DC (DC power)
Input 24V DC °C common
Output 2 A 0.5 A
Service power supply
(AC power type only)
0.15 A (C14)/ 0.4 A (C30/ C60)
Performance Specifications Number of I/O points C14 Input: 8 points, Output: 6 points
C30 Input: 16 points, Output: 14 points
C60 Input: 32 points, Output: 28 points
I/O points when expanded C14 Max. 328 points (When using FP0 expnasion unita and add-on cassette)
C30 Max. 352 points (When using FP0 expnasion unita and add-on cassette)
C60 Max. 382 points (When using FP0 expnasion unita and add-on cassette)
Operation speed 0.32μs/step
Program memory Flash ROM built-in (no battery backup required)
Program capcity 16 ksteps (C14), 32 ksteps (C30, C60)
Basic instructions 111
Applied instructions 216
Operation memory Internal relay ® 4096 points
Timer/counter (T/C) 1024 points
Data register (DT) 256 words
Special functions Pulse catch input 14 points 14 points
Interrupt input 14 points 14 points
Analog I/O Input: Max. 24 ch, Output: Max. 12 ch (When using FP0 analog unit)
Input: Max. 4 ch (When using add-on cassette)
Volume input 2 points (C14/C30), 4 points (C60)
High-speed counter Input of main unit Single-phase: 8 ch x Max. 10 kHz
2-phase: 4 ch Max. 5 kHz
Single-phase: 8 ch (High-speed: 4 ch, midium-speed: 4 ch)
2-phase: 4 ch (High-speed: 2 ch, midium-speed: 2ch)

With high-speed single-phase:
1 ch x Max. 100 kHz
2 ch x Max. 80 kHz
3 ch x Max. 60 kHz
4 ch x Max. 50 kHz
With high-speed 2-phase:
1 ch x Max. 35 kHz
2 ch x Max. 25 kHz
With medium-speed single-phase:
4 ch x Max. 10 kHz each
With Medium-speed 2-phase:
2 ch x Max. 5 kHz each

when pulse I/Ocassette installed Single-phase: 2 ch x Max. 80 kHz, 4 ch x Max. 50 kHz
2-phase: 1 ch x Max. 30 kHz, 2 ch x Max. 25 kHz
Pulse I/O cassette cannot be installed.
Pulse output Input of main unit With high-speed 2 ch x Max. 100 kHz
For linear interpolation, compositespeed: 100 kHz
With medium-speed 2 ch x Max. 20 kHz
For linear interpolation, compositespeed: 20 kHz
when pulse I/Ocassette installed 1 ch x Max. 100 kHz, 2ch x Max. 80 kHz Pulse I/O cassette cannot be installed.
Serial interface RS232C.RS485, USB, Ethernet
Network function PLC Link, Computer link, Modem, Modbus-RTU
Other functions Program editing during RUN, Constant scan, 8-digit password, Program