Cylindrical Cable Outgoing Connector Type Proximity Sensor
Cable outgoing connector type proximity sensor PRW Series features world-best class superior noise resistance characteristics with exclusively designed IC. Also, this series is more convenient as the user only need to replace the main body during maintenance.
Features
Ordering Information
Specification Table
• DC 2-wire type
Model | PRWT08-1.5DO PRWT08-1.5DC PRWT08-1.5DO-I PRWT08-1.5DC-I PRWT08-1.5DO-V PRWT08-1.5DC-V PRWT08-1.5DO-I V PRWT08-1.5DC-I V |
PRWT08-2DO PRWT08-2DC PRWT08-2DO-I PRWT08-2DC-I PRWT08-2DO-I V PRWT08-2DC-I V |
PRWT12-2[D]O PRWT12-2[D]C PRWT12-2[D]O-I PRWT12-2[D]C-I |
PRWT12-4[D]O PRWT12-4[D]C PRWT12-4[D]O-I PRWT12-4[D]C-I |
PRWT18-5[D]O PRWT18-5[D]C PRWT18-5[D]O-I PRWT18-5[D]C-I |
PRWT18-8[D]O PRWT18-8[D]C PRWT18-8[D]O-I PRWT18-8[D]C-I |
PRWT30-10[D]O PRWT30-10[D]C PRWT30-10[D]O-I PRWT30-10[D]C-I PRWT30-10[D]O- V PRWT30-10[D]C-IV |
PRWT30-15[D]O PRWT30-15[D]C PRWT30-15[D]O-I PRWT30-15[D]C-I PRWT30-15[D]O-V PRWT30-15[D]C-IV |
|
Sensing distance | 1.5mm | 2mm | 4mm | 5mm | 8mm | 10mm | 15mm | ||
Hysteresi | Max. 10% of sensing distance | ||||||||
Standard sensing target | 8x8x1mm (lron) |
12x12x1mm (lron) |
18x18x1mm (Iron) | 25x25x1mm (Iron) | 30x30x1mm (Iron) | 45x45x1 mm (Iron) | |||
Setting distance | 0 to 1.05mm | 0 to 1.4mm | 0 to 2.8mm | 0 to 3.5mm | 0 to 5.6mm | 0 to 7mm | 0 to 10.5mm | ||
Power supply (Operation voltage) | 12-24VDC (10-30VDC) |
||||||||
Leakage current | Max. 0.6mA | ||||||||
Response frequency※1 | 1.5kHz | 1kHz | 1.5kHz | 500Hz | 350Hz | 400Hz | 200Hz | ||
Residual voltage※2 | Max. 3.5V(Non-polarity type Is Max. 5V) | ||||||||
Affection by Temp. | Max. ±10% for sensing distance at ambient temperature 20℃(For PRWT08 series : ±20% Max,) | ||||||||
Control output | 2 to 100mA | ||||||||
Insulation resistance | Min. 50MΩ(at 500VDC meggera) | ||||||||
Dielectric strength | 1500VAC 50/60Hz for 1 minute | ||||||||
Vibration | 1mm amplitude at frequency of 10 to 55Hz(for 1 min.) in each of X, Y, Z directions for 2 hours | ||||||||
Shock | 500m/s²(approx. 50G)in each of X, Y, Z directions for 3 times | ||||||||
Indicator | Operation indicator(red LED) | ||||||||
Environment | Ambient temperature | -25 to 70℃, storage : -30 to 80℃ | |||||||
Ambient humidity | 35 to 95% RH, storage :35 to 95% RH | ||||||||
Protection circuit | Surge protection circuit | Surge protection circuit, Overcurrent protection circuit | |||||||
Protection | IP67(IEC standard) | ||||||||
Material | Case/Nut: Nikel plated Brass, Washer: Nikel plated Iron, Sensing surface: PBT, Standard cable(Black): Polyvinyl chloride(PVC), Oil resistant cable(Gray): Oil resistant Polyvinyl chloride(PVC) |
||||||||
Cable | ø4, 2-wire, 300mm, M12 connector | ø5, 2-wire, 300mm, M12 connector | |||||||
Approval | CE | ||||||||
Unit weight※3 | Approx. 44g (Approx. 32g) |
Approx. 54g (Approx. 42g) |
Approx.70g (Approx. 58g) |
Approx. 134g (Approx. 122g) |
※When the [ ] model name is X, it is non-polarity model
※1: The response frequency is the average value. The standard sensing target is used and the width is set as 2 times of the standard sensing target, 1/2 of the sensing distance for the distance.
※2: Before using non-polarity type, check the condition of connected device because residual voltage is 5V.
※3: The weight with packaging and the weight in parentheses is only unit weight.
※Please fasten the vibration part with Teflon type.
※The ‘□’ of model name is for power type. ‘D’ is 12-24VDC, ‘X’ is non-polarity 12-24VDC.
※The last ‘V’ of model name is for the model with oil-resistance reinforced cable.
※Environment resistance is rated at no freezing or condensation.
• DC 3-wire type
Model | PRW08-1.5DN PRW08-1.5DP PRW08-1.5DN2 PRW08-1.5DP2 PRW08-1.5DN-V PRW08-1.5DP-V PRWL08-1.5DN PRWL08-1.5DP PRWL08-1.5DN2 PRWL08-1.5DP2 |
PRW08-2DN PRW08-2DP PRW08-2DN2 PRW08-2DP2 PRW08-2DN-V PRW08-2DP-V PRWL08-2DN PRWL08-2DP PRWL08-2DN2 PRWL08-2DP2 |
PRW12-2DN PRW12-2DP PRW12-2DN2 PRW12-2DP2 |
PRW12-4DN PRW12-4DP PRW12-4DN2 PRW12-4DP2 |
PRW18-5DN PRW18-5DP PRW18-5DN2 PRW18-5DP2 PRWL18-5DN PRWL18-5DP PRWL18-5DN2 PRWL18-5DP2 |
PRW18-8DN PRW18-8DP PRW18-8DN2 PRW18-8DP2 PRWL18-8DN PRWL18-8DP PRWL18-8DN2 PRWL18-8DP2 |
PRW30-10DN PRW30-10DP PRW30-10DN2 PRW30-10DP2 PRW30-10DN-V PRW30-10DP-V PRWL30-10DN PRWL30-10DP PRWL30-10DN2 PRWL30-10DP2 |
PRW30-15DN PRW30-15DP PRW30-15DN2 PRW30-15DP2 PRW30-15DN-V PRW30-15DP-V PRWL30-15DN PRWL30-15DP PRWL30-15DN2 PRWL30-15DP2 |
|
Sensing distance | 1.5mm | 2mm | 4mm | 5mm | 8mm | 10mm | 15mm | ||
Hysteresis | Max. 10% of sensing distance | ||||||||
Standard sensing target | 8×8×1mm (Iron) |
12x12x1mm (lron) |
18x18x1mm(lron) | 25×25×1mm(Iron) | 30x30x1mm(lron) | 45x45x1 mm(lron) | |||
Setting distance | 0 to 1.05mm | 0 to 1.4mm | 0 to 2.8mm | 0 to 3.5mm | 0 to 5.6mm | 0 to 7mm | 0 to 10.5mm | ||
Power supply (Operation voltage) | 12-24VDC (10-30VDC) |
||||||||
Current consumption | Max. 10mA | ||||||||
Response frequency※1 | 1.5kHz | 1kHz | 1.5kHz | 500Hz | 350Hz | 400Hz | 200Hz | ||
Residual voltage | Max. 2V | Max. 1.5 V | |||||||
Affection by Temp. | Max. ±10% for sensing distance at ambient temperature 20℃(For PRW(L)08 series : ±20% Max,) | ||||||||
Control output | 200mA | ||||||||
Insulation resistance | Min. 50MΩ(at 500VDC megger) | ||||||||
Dielectric strength | 1500VAC 50/60Hz for 1 minute | ||||||||
Vibration | 1mm amplitude at frequency of 10 to 55Hz(for 1 min.) in each of X, Y, Z directions for 2 hours | ||||||||
Shock | 500m/s²(approx. 50G) in each of X, Y, Z directions for 3 times | ||||||||
Indicator | Operation indicator(red LED) | ||||||||
Environ -ment |
Ambient temperature | -25 to 70℃, storage : -30 to 80℃ | |||||||
Ambient humidity | 35 to 95%RH, storage :35 to 95%RH | ||||||||
Protection circuit | Surge protection circuit, Reverse polarity proteciton circuit, Overcurrent protection circuit | ||||||||
Protection | IP67(IEC standard) | ||||||||
Material | Case/Nut: Nikel plated Brass, Washer: Nikel plated Iron, Sensing surface: PBT, Standard cable(Black): Polyvinyl chloride(PVC), Oil resistant cable(Gray): Oil resistant Polyvinyl chlorde(PVC) |
||||||||
Cable | ø4, 3-wire, 300mm, M12 connector | ø5, 3-wire, 300mm, M12 connector | |||||||
Approval | CE | ||||||||
Unit weight※2 | PRW: Approx. 44g( Approx. 32g) PRWL: Approx. 46g(Approx. 34g) |
Approx. 54g(Approx. 42g) | PRW: Approx. 70g(Approx. 58g) PRWL: Approx. 90g(Approx. 78g) |
PRW: Approx. 134g(Approx. 122g) PRWL:Approx. 195g(Approx. 158g) |
• AC 2-wire type
Model | PRW12-2AO PRW12-2AC |
PRW12-4AO PRW12-4AC |
PRW18-5AO PRW18-5AC PRWL18-5AO PRWL18-5AC |
PRW18-8AO PRW18-8AC PRWL18-8AO PRWL18-8AC |
PRW30-10AO PRW30-10AC PRWL30-10AO PRWL30-10AC |
PRW30-15AO PRW30-15AC PRWL30-15AO PRWL30-15AC |
|
Sensing distance | 2mm | 4mm | 5mm | 8mm | 10mm | 15mm | |
Hysteresis | Max. 10% of sensing distance | ||||||
Standard sensing target | 12x12x1mm (lron) |
18x18x1mm(lron) | 25x25x1mm(lron) | 30x30x1mm(lron) | 45x45x1mm(lron) | ||
Setting distance | 0 to 1.4mm | 0 to 2.8mm | 0 to 3.5mm | 0 to 5.6mm | 0 to 7mm | 0 to 10.5mm | |
Power supply (Operation voltage) | 100-240VAC (85-264VAC) |
||||||
Leakage current | Max. 2.5mA | ||||||
Response frequency※1 | 20Hz | ||||||
Residual voltage | Max. 10V | ||||||
Affection by Temp. | Max. ±10% for sensing distance at ambient temperature 20℃ | ||||||
Control output | 5 to 150mA | 15 to 200mA | |||||
Insulation resistance | Min. 50MΩ(at 500VDC megger) | ||||||
Dielectric strength | 2.500VAC 50/60Hzfor 1 minute | ||||||
Vibration | 1mm amplitude at frequency of 10 to 55Hz(for 1 mln.) in each of X, Y, Z directions for 2 hours | ||||||
Shock | 500m/s²(approx. 50G) in each of X, Y, Z directions for 3 times | ||||||
Indicator | Operation indicator(red LED) | ||||||
Environment | Ambient temperature | -25 to 70℃, storage : -30 to 80℃ | |||||
Ambient humidity | 35 to 95%RH, storage :35 to 95%RH | ||||||
Protection circuit | Surge protection circuit | ||||||
Protection | IP67(IEC standard) | ||||||
Material | Case/Nut: Nikel plated Brass, Washer: Nikel plated Iron, Sensing surface: PBT, Standard cable(Black): Polyvinyl chloride(PVC) |
||||||
Cable | ø4, 2-wire, 300mm, M12 connector | ø5, 2-wire, 300mm, M12 connector | |||||
Approval | CE | ||||||
Unit weight※2 | Approx. 54g(Approx. 42g) | PRW: Approx. 78g (Approx. 66g) PRWL: Approx. 90g (Approx. 78g) |
PRW: Approx. 134g(Approx. 122g) PRWL: Approx. 195g(Approx. 158g) |
※1: The response frequency is the average value. The standard sensing target is used and the width is set as 2 times of the standard sensing target, 1/2 of the sensing distance for the distance.
※2: The weight with packaging and the weight in parentheses is only unit weight.
※The last ‘V’ of model name is for the model with oil-resistance reinforced cable.
※Environment resistance is rated at no freezing or condensation.
Dimensions
Connections
User’s Guide
Caution for your safety