WENTION TECHNOLOGY SDN BHD

Your Most Reliable Factory Automation Channel

PRODUCTS

PRW Series

Cylindrical Cable Outgoing Connector Type Proximity Sensor
Cable outgoing connector type proximity sensor PRW Series features world-best class superior noise resistance characteristics with exclusively designed IC. Also, this series is more convenient as the user only need to replace the main body during maintenance.

100531125332

Share this

Features

  • Shorten the time of maintenance with the body
  • Improved the noise resistance with dedicated IC
  • Built-in reverse polarity protection circuit (DC 3-wire type)
  • Built-in surge protection circuit
  • Built-in overcurrent protect protection circuit
  • Waterproof structure IP67 (IEC standard)
  • Replaceable for micro switches and limit switches

 

Ordering Information

PRW-7

 

Specification Table

• DC 2-wire type

Model PRWT08-1.5DO
PRWT08-1.5DC
PRWT08-1.5DO-I
PRWT08-1.5DC-I
PRWT08-1.5DO-V
PRWT08-1.5DC-V
PRWT08-1.5DO-I V
PRWT08-1.5DC-I V
PRWT08-2DO
PRWT08-2DC
PRWT08-2DO-I
PRWT08-2DC-I
PRWT08-2DO-I V
PRWT08-2DC-I V
PRWT12-2[D]O
PRWT12-2[D]C
PRWT12-2[D]O-I
PRWT12-2[D]C-I
PRWT12-4[D]O
PRWT12-4[D]C
PRWT12-4[D]O-I
PRWT12-4[D]C-I
PRWT18-5[D]O
PRWT18-5[D]C
PRWT18-5[D]O-I
PRWT18-5[D]C-I
PRWT18-8[D]O
PRWT18-8[D]C
PRWT18-8[D]O-I
PRWT18-8[D]C-I
PRWT30-10[D]O
PRWT30-10[D]C
PRWT30-10[D]O-I
PRWT30-10[D]C-I
PRWT30-10[D]O- V
PRWT30-10[D]C-IV
PRWT30-15[D]O
PRWT30-15[D]C
PRWT30-15[D]O-I
PRWT30-15[D]C-I
PRWT30-15[D]O-V
PRWT30-15[D]C-IV
Sensing distance 1.5mm 2mm 4mm 5mm 8mm 10mm 15mm
Hysteresi Max. 10% of sensing distance
Standard sensing target 8x8x1mm
(lron)
12x12x1mm
(lron)
18x18x1mm (Iron) 25x25x1mm (Iron) 30x30x1mm (Iron) 45x45x1 mm (Iron)
Setting distance 0 to 1.05mm 0 to 1.4mm 0 to 2.8mm 0 to 3.5mm 0 to 5.6mm 0 to 7mm 0 to 10.5mm
Power supply (Operation voltage) 12-24VDC
(10-30VDC)
Leakage current Max. 0.6mA
Response frequency※1 1.5kHz 1kHz 1.5kHz 500Hz 350Hz 400Hz 200Hz
Residual voltage※2 Max. 3.5V(Non-polarity type Is Max. 5V)
Affection by Temp. Max. ±10% for sensing distance at ambient temperature 20℃(For PRWT08 series : ±20% Max,)
Control output 2 to 100mA
Insulation resistance Min. 50MΩ(at 500VDC meggera)
Dielectric strength 1500VAC 50/60Hz for 1 minute
Vibration 1mm amplitude at frequency of 10 to 55Hz(for 1 min.) in each of X, Y, Z directions for 2 hours
Shock 500m/s²(approx. 50G)in each of X, Y, Z directions for 3 times
Indicator Operation indicator(red LED)
Environment Ambient temperature -25 to 70℃, storage : -30 to 80℃
Ambient  humidity 35 to 95% RH, storage :35 to 95% RH
Protection circuit Surge protection circuit Surge protection circuit, Overcurrent protection circuit
Protection IP67(IEC standard)
Material Case/Nut: Nikel plated Brass, Washer: Nikel plated Iron, Sensing surface: PBT,
Standard cable(Black): Polyvinyl chloride(PVC), Oil resistant cable(Gray): Oil resistant Polyvinyl chloride(PVC)
Cable ø4, 2-wire, 300mm, M12 connector ø5, 2-wire, 300mm, M12 connector
Approval CE
Unit weight※3 Approx. 44g
(Approx. 32g)
Approx. 54g
(Approx. 42g)
Approx.70g
(Approx. 58g)
Approx. 134g
(Approx. 122g)

※When the [ ] model name is X, it is non-polarity model
※1: The response frequency is the average value. The standard sensing target is used and the width is set as 2 times of the standard sensing target, 1/2 of the sensing distance for the distance.
※2: Before using non-polarity type, check the condition of connected device because residual voltage is 5V.
※3: The weight with packaging and the weight in parentheses is only unit weight.
※Please fasten the vibration part with Teflon type.
※The ‘□’ of model name is for power type. ‘D’ is 12-24VDC, ‘X’ is non-polarity 12-24VDC.
※The last ‘V’ of model name is for the model with oil-resistance reinforced cable.
※Environment resistance is rated at no freezing or condensation.

 

• DC 3-wire type 

 Model PRW08-1.5DN
PRW08-1.5DP
PRW08-1.5DN2
PRW08-1.5DP2
PRW08-1.5DN-V
PRW08-1.5DP-V
PRWL08-1.5DN
PRWL08-1.5DP
PRWL08-1.5DN2
PRWL08-1.5DP2
PRW08-2DN
PRW08-2DP
PRW08-2DN2
PRW08-2DP2
PRW08-2DN-V
PRW08-2DP-V
PRWL08-2DN
PRWL08-2DP
PRWL08-2DN2
PRWL08-2DP2
PRW12-2DN
PRW12-2DP
PRW12-2DN2
PRW12-2DP2
PRW12-4DN
PRW12-4DP
PRW12-4DN2
PRW12-4DP2
PRW18-5DN
PRW18-5DP
PRW18-5DN2
PRW18-5DP2
PRWL18-5DN
PRWL18-5DP
PRWL18-5DN2
PRWL18-5DP2
PRW18-8DN
PRW18-8DP
PRW18-8DN2
PRW18-8DP2
PRWL18-8DN
PRWL18-8DP
PRWL18-8DN2
PRWL18-8DP2
PRW30-10DN
PRW30-10DP
PRW30-10DN2
PRW30-10DP2
PRW30-10DN-V
PRW30-10DP-V
PRWL30-10DN
PRWL30-10DP
PRWL30-10DN2
PRWL30-10DP2
PRW30-15DN
PRW30-15DP
PRW30-15DN2
PRW30-15DP2
PRW30-15DN-V
PRW30-15DP-V
PRWL30-15DN
PRWL30-15DP
PRWL30-15DN2
PRWL30-15DP2
Sensing distance 1.5mm 2mm 4mm 5mm 8mm 10mm 15mm
Hysteresis Max. 10% of sensing distance
Standard sensing target 8×8×1mm
(Iron)
12x12x1mm
(lron)
18x18x1mm(lron) 25×25×1mm(Iron) 30x30x1mm(lron) 45x45x1 mm(lron)
Setting distance 0 to 1.05mm 0 to 1.4mm 0 to 2.8mm 0 to 3.5mm 0 to 5.6mm 0 to 7mm 0 to 10.5mm
Power supply (Operation voltage) 12-24VDC
(10-30VDC)
Current consumption Max. 10mA
Response frequency※1 1.5kHz 1kHz 1.5kHz 500Hz 350Hz 400Hz 200Hz
Residual voltage Max. 2V Max. 1.5 V
Affection by Temp. Max. ±10% for sensing distance at ambient temperature 20℃(For PRW(L)08 series : ±20% Max,)
Control output 200mA
Insulation resistance Min. 50MΩ(at 500VDC megger)
Dielectric strength 1500VAC 50/60Hz for 1 minute
Vibration 1mm amplitude at frequency of 10 to 55Hz(for 1 min.) in each of X, Y, Z directions for 2 hours
Shock 500m/s²(approx. 50G) in each of X, Y, Z directions for 3 times
Indicator Operation indicator(red LED)
Environ
-ment
Ambient temperature -25 to 70℃, storage : -30 to 80℃
Ambient humidity 35 to 95%RH, storage :35 to 95%RH
Protection circuit Surge protection circuit, Reverse polarity proteciton circuit, Overcurrent protection circuit
Protection IP67(IEC standard)
Material Case/Nut: Nikel plated Brass, Washer: Nikel plated Iron, Sensing surface: PBT,
Standard cable(Black): Polyvinyl chloride(PVC), Oil resistant cable(Gray): Oil resistant Polyvinyl chlorde(PVC)
Cable ø4, 3-wire, 300mm, M12 connector ø5, 3-wire, 300mm, M12 connector
Approval CE
Unit weight※2 PRW: Approx. 44g( Approx. 32g)
PRWL: Approx. 46g(Approx. 34g)
Approx. 54g(Approx. 42g) PRW: Approx. 70g(Approx. 58g)
PRWL: Approx. 90g(Approx. 78g)
PRW: Approx. 134g(Approx. 122g)
PRWL:Approx. 195g(Approx. 158g)


• AC 2-wire type 

Model PRW12-2AO
PRW12-2AC
PRW12-4AO
PRW12-4AC
PRW18-5AO
PRW18-5AC
PRWL18-5AO
PRWL18-5AC
PRW18-8AO
PRW18-8AC
PRWL18-8AO
PRWL18-8AC
PRW30-10AO
PRW30-10AC
PRWL30-10AO
PRWL30-10AC
PRW30-15AO
PRW30-15AC
PRWL30-15AO
PRWL30-15AC
Sensing distance 2mm 4mm 5mm 8mm 10mm 15mm
Hysteresis Max. 10% of sensing distance
Standard sensing target 12x12x1mm
(lron)
18x18x1mm(lron) 25x25x1mm(lron) 30x30x1mm(lron) 45x45x1mm(lron)
Setting distance 0 to 1.4mm 0 to 2.8mm 0 to 3.5mm 0 to 5.6mm 0 to 7mm 0 to 10.5mm
Power supply (Operation voltage) 100-240VAC
(85-264VAC)
Leakage current Max. 2.5mA
Response frequency※1 20Hz
Residual voltage Max. 10V
Affection by Temp. Max. ±10% for sensing distance at ambient temperature 20℃
Control output 5 to 150mA 15 to 200mA
Insulation resistance Min. 50MΩ(at 500VDC megger)
Dielectric strength 2.500VAC 50/60Hzfor 1 minute
Vibration 1mm amplitude at frequency of 10 to 55Hz(for 1 mln.) in each of X, Y, Z directions for 2 hours
Shock 500m/s²(approx. 50G) in each of X, Y, Z directions for 3 times
Indicator Operation indicator(red LED)
Environment Ambient temperature -25 to 70℃, storage : -30 to 80℃
Ambient humidity 35 to 95%RH, storage :35 to 95%RH
Protection circuit Surge protection circuit
Protection IP67(IEC standard)
Material Case/Nut: Nikel plated Brass, Washer: Nikel plated Iron, Sensing surface: PBT,
Standard cable(Black): Polyvinyl chloride(PVC)
Cable ø4, 2-wire, 300mm, M12 connector ø5, 2-wire, 300mm, M12 connector
Approval CE
Unit weight※2 Approx. 54g(Approx. 42g) PRW: Approx. 78g (Approx. 66g)
PRWL: Approx. 90g (Approx. 78g)
PRW: Approx. 134g(Approx. 122g)
PRWL: Approx. 195g(Approx. 158g)

※1: The response frequency is the average value. The standard sensing target is used and the width is set as 2 times of the standard sensing target, 1/2 of the sensing distance for the distance.
※2: The weight with packaging and the weight in parentheses is only unit weight.
※The last ‘V’ of model name is for the model with oil-resistance reinforced cable.
※Environment resistance is rated at no freezing or condensation.

 

Dimensions

PRW-8

 

Connections

PRW-9

 

User’s Guide

PRW-10

 

Caution for your safety

PRW-11